DATA-CENTER POWER / TEXAS, USA
FUJI ELECTRICUPS7000HX-T3U/225

Fuji Electric
500kVA UPS

Online double-conversion UPS systems for data centers and critical-power projects. Never powered, with zero run hours reported by the owner.

100SYSTEMS IN THE OFFER
PRICING BY QUOTATIONYour quantity. Your project.

Inventory owned by Nobby. Current availability and terms confirmed with your quote.

See actual equipment
Estimated delivery: approximately 6 weeks

Subject to receipt of pending boards from Fuji Electric.

ACTUAL INVENTORYTEXAS
500kWRATED OUTPUT / UNIT
480VTHREE-PHASE AC
60HzNAMEPLATE FREQUENCY
CONDITION DISCLOSURENever powered, owner-reported. Water event disclosed.
THE PLATFORMOnline double-conversion
MODEL CAPABILITYUp to 8 units in parallel*
CATALOG EFFICIENCYUp to 97.5%*
Review the specifications

*Manufacturer design specifications. Subject to engineering and operating conditions; not verified operating performance of this lot.

02 / YOUR REQUIREMENT

Built for critical loads.
Offered at serious scale.

One hundred 500kVA systems in Texas, originally placed for a deployment that did not proceed. Explore the quantity that fits your project and request current terms.

EXPLORE YOUR REQUIREMENT

How much power
are you planning for?

Choose a quantity to see its combined rated output.

1 UNIT100 UNITS
COMBINED RATED OUTPUT
5MW

10 units × 500kW per unit

10 selected100 units in the total inventory

*Capacity is the sum of individual nameplate ratings, not a proposed parallel system. System design, quantity availability and purchase terms are subject to confirmation.

03 / EXPLORE THE ENGINEERING

See what makes
the Fuji platform different.

Four manufacturer design features, brought to life. Explore the engineering behind the UPS7000HX-T3U.

FOUR INTERACTIVE DEMOS

Choose a tab to change the animation

01 / EXPANSION

Start with one.
Think bigger.

The platform supports up to eight units in parallel, giving engineers flexibility to plan a larger system.

8units in an engineered
parallel configuration

Parallel switchgear, controls and site engineering are additional. Combined nameplate ratings do not establish usable or redundant system capacity.

Engineering illustration

Manufacturer design features. Illustrations are schematic. They do not show the condition, testing or commissioning of this lot.

View Fuji’s technical reference ↗
04 / TECHNICAL PROFILE

Powerful numbers.
Precisely stated.

The UPS7000HX-T3U platform uses online double-conversion with Fuji’s RB-IGBT technology. The published unit nameplate confirms the 500kVA / 500kW rating.

MANUFACTURER’S CATALOG RATING97.5%

Maximum observed efficiency for the 500kVA model. Actual operating performance depends on load and conditions.

PDFManufacturer specification sheetUPS7000HX-T3U · Technical referencePDFHX series brochureArchitecture, features & service access

Manufacturer literature describes the product family. Catalog warranty and accessory references do not establish coverage or inclusions for this surplus offer.

TECHNICAL PROFILE500kVA MODEL
Model / type
UPS7000HX-T3U/225
Rated output
500kVA / 500kW
AC input & output
480V · Three-phase · 60Hz
Topology
Online double-conversion
AT-NPC 3-Level · RB-IGBT
Input / output current
620A / 601A nominal
Rated power factor
1.0
Battery voltage
480VDC on nameplate
Batteries are not included
Catalog dimensions
90.6″ W × 35.4″ D × 78.7″ H
Published unit weight
2,010kg on nameplate
Published manufacture date
April 2023 · Made in Japan

Identification and weight refer to the photographed unit, W. No. HHPM9501UM004. Confirm each purchased unit and its shipping dimensions before transport.

05 / MONITORING & CONTROL

See the power.
Stay informed.

From the front touchscreen to optional remote connections, the Fuji platform puts useful operating information within reach.

INTERACTIVE DEMOSimulated · No equipment connection
Fuji T3U status demonstration: normal operation Simulated normal inverter operation. Green input, rectifier, inverter and output blocks are connected by an animated power path. Bypass is available but is not carrying the load. Battery voltage and other readings are illustrative. This is not a live connection or a test of the offered units. RUNNING STATUSDEMO 00:00:00 DEMO · NORMAL OPERATION BYP-V 480V SYNC BYP IN REC INV OUT BC IN-V 480V OUT-V480V BAT-V535V The inverterhas driven.
Based on Fuji’s T3U panel. Readings and warning styling are illustrative; installed firmware may differ.
NORMAL OPERATION / SIMULATION

Follow the power.
At a glance.

The rectifier and inverter supply the load. Bypass is available on standby.

MODENormal operation

Normal flow shown in the manufacturer brochure.

SAMPLE OUTPUT300kW
SAMPLE LOAD60.0%
OUTPUT FREQUENCY60.0Hz

External batteries are shown for demonstration. Batteries are excluded from this offer.

Choose a status

SELECT A CIRCLE TO EXPLORE

Documented Fuji alarms; simulated visuals and values. Setpoints and transfer timing are not reproduced. Silent preview. Model-specific alarm reference ↗

Static demonstrationIN: input · REC: rectifier · INV: inverter · BC: battery converter
Compare with Fuji’s original control-panel photo
Fuji brochure photograph of the T3U panel: gray bezel, blue running-status header, green BYP, IN, REC, INV, OUT and BC blocks
MANUFACTURER REFERENCE

The starting point.

This is the panel photograph in the supplied Fuji brochure, not a photograph of an operating unit from this lot. The recreation follows its colors, labels and diagram arrangement. The status controls, alarm banners, warning colors and moving highlights are added for this demonstration. Exact alarm names come from Fuji’s T3U guide; the brochure does not show alarm-state screenshots.

Open Fuji brochure · page 3 ↗
AT THE UNIT

Useful readings.
One touchscreen.

View electrical measurements and system information on the front color touchscreen, with access to operating settings.

DIAGNOSTICS

A record to
work from.

Active alarms and time-stamped event history give technicians information to help investigate operating events.

TEST CONTROLS

Battery checks.
Defined settings.

Set battery-test duration and end voltage, and initiate a manual test through the operator interface.

Batteries are not included in this offer.
OPTIONAL HARDWARE

Visibility beyond
the cabinet.

A Web/SNMP card enables browser monitoring and email alerts. A Modbus card supports connection to compatible monitoring systems.

Installed communications options require confirmation.

Features described in Fuji’s guide specification. Firmware and communications hardware for this lot are subject to confirmation.

Fuji controls & monitoring reference ↗
06 / DELIVERY OUTLOOK

A clear view
of what comes next.

The units are in Texas. Delivery depends on receipt of the pending control boards from Fuji Electric, whose production is delayed.

CURRENT DELIVERY ESTIMATE
6weeks
approximately

Subject to Fuji board delivery.
Confirm the current schedule with your quote.

07 / CONDITION & INCLUSIONS

Know the equipment.
Know the full story.

Never powered and zero run hours are owner-reported. Review the event history and the scope of the offer before making a purchasing decision.

01

Never powered.
Water event disclosed.

A humidifier line failed three levels above where the units were stored. The existing offer record reports less than one inch of water on the ground around the units, for less than four hours.

The units were set in place but never powered on. Inspection and unit-specific verification remain part of buyer diligence.

Discuss condition with our team
+

The offered equipment

Fuji Electric UPS7000HX-T3U/225 systems. Pending control boards and the delivery schedule will be confirmed in the quote.

−

Not included or represented

Batteries, installation, commissioning, warranty and unlisted accessories are not represented as included.

↗

Inspect and verify

Request serial details and discuss inspection. No complete 100-unit serial list is published; verify the identity and condition of each purchased unit.

08 / BUYER QUESTIONS

Details that
move things forward.

How many systems are in the offer?

The total inventory is 100 Fuji Electric 500kVA / 500kW UPS systems in Texas. Tell us the quantity you need; availability and purchase terms will be confirmed with your quote.

What is the price?

Pricing is provided by quotation. Submit your required quantity and project details to receive current terms.

When can the systems be delivered?

The current estimate is approximately six weeks, subject to receiving the pending control boards from Fuji Electric. This is an estimate, not a guaranteed delivery date. Confirm the latest schedule when requesting a quote.

Are batteries and commissioning included?

No. Batteries, installation, commissioning and warranty are not represented as included. The scope of the purchase will be confirmed in the quote.

What happens before shipment?

Before ordering, confirm in writing who will install the pending control boards, the inspection or testing scope, any available reports, and the shipment schedule. Board installation, functional testing and a written test report are not promised by this listing.

Can I review the equipment before buying?

Contact the team to discuss inspection and request unit-specific information. The gallery shows actual inventory photographs; the manufacturer documents describe the product family. The water-event disclosure applies to the offer.

YOUR NEXT POWER PROJECT STARTS HERE

Let’s talk
critical power.

Tell us your quantity, destination and timeline.
We’ll discuss pricing, scope and delivery.

100 units · Texas · Approximately 6 weeks*

*Delivery estimate is subject to receipt of the pending boards from Fuji Electric. Equipment is subject to prior sale and final transaction terms.

100 units · 500kVA each
FUJI ELECTRIC / 500kVA UPS

Let’s build your quote.

100 units · Texas · Estimated delivery approximately six weeks, subject to Fuji board delivery.

We use these details to respond to your request. Privacy policy.