Proven Performer  /  Commercial HVAC
New unused surplus · Houston, Texas

Daikin RCS040D Applied-split condensing units

A documented offering of 20 commercial, cooling-only condensing units configured for 460V, three-phase service. Condensing units only—air handlers are not included.

R-410A460V / 3Ø / 60HzDual refrigerant circuitsFour scroll compressors
Row of Daikin RCS040D condensing units photographed in outdoor storage
Current inventory photography
20units
available
RCS040DDaikin model
422,754 BTU/hSelected refrigeration effect
14.9 IEERSubmittal efficiency
2,496 lbOperating weight per unit
Houston, TXFOB location reported
The offering

Commercial cooling capacity,
clearly documented.

The seller reports 20 new, unused Daikin RCS040D condensing units. The equipment is identified for cooling-only operation using R-410A refrigerant and 460V / 3-phase / 60Hz electrical service.

The supplied Daikin submittal schedules the RCS040D at 422,754 BTU/h total refrigeration effect under the stated selection conditions. The equipment is commonly identified by its 40-ton model class; actual capacity depends on design and operating conditions.

Current photographs show the units in outdoor storage and include cabinet, compressor, coil, fan-guard, nameplate and loading views.

Current walkaround video

See the Daikin RCS040D up close.

This concise edit of seller-supplied footage shows the offered condensing units’ exterior cabinet, Daikin equipment plate, compressor section, electrical controls, wiring and cabinet diagrams.

51-second editAudio removedActual equipment footage

Only footage identified as the Daikin RCS040D equipment is included. Separate footage showing other HVAC equipment was excluded from this edit.

Daikin RCS040DMuted inspection edit
Supplied technical data

RCS040D at a glance.

Values below are taken from the supplied Daikin condenser submittal and a photographed unit nameplate. Project-specific performance and compatibility should be reviewed by the buyer’s qualified HVAC and electrical professionals.

Performance & refrigeration

ModelRCS040D
Total refrigeration effect422,754 BTU/h
Unit power38.8 kW
Efficiency11.3 EER / 14.9 IEER
RefrigerantR-410A
Refrigerant circuits2
Compressors4 scroll compressors
Condenser fans4

Electrical & physical

Power supply460V / 3-phase / 60Hz
Minimum circuit ampacity80.6 A submittal / 80.7 A nameplate
Maximum overcurrent protection90 A
Dimensions80.0 × 55.5 × 99.0 in.
Operating weight2,496 lb
Suction connections(2) 1.62 in.
Liquid connections(2) 0.88 in.
Hot-gas bypass connections(2) 0.88 in.

Verification note: Electrical values and connection details should be confirmed against the nameplate and documentation for the specific unit selected. Short-circuit current ratings shown in the supplied materials should also be reconciled before installation design.

Documented configuration

Specified equipment features.

The supplied RCS040D submittal lists the following configuration and options for the scheduled condenser unit.

Dual refrigeration circuits

Two refrigerant circuits with multiple scroll compressors provide the scheduled refrigeration configuration.

Low-ambient operation

Speedtrol low-ambient control is listed for operation down to 0°F.

Electrofin coil coating

Electrofin condenser-coil coating is listed in the supplied unit options.

Built-in hail protection

The submittal identifies built-in hail protection among the scheduled options.

Factory electrical equipment

A thru-door disconnect, ground-fault protection and factory-powered GFI service outlet are listed.

Service connections

Refrigeration service valves and hot-gas bypass tee connections are identified in the option schedule.

Source documents

Review the supplied submittals.

The complete documents supplied with the offering are available here for technical review.

Straight answers

Frequently asked questions.

Only what the supplied records and photographs support.

What equipment is included?

The offering is for Daikin RCS040D condensing units only. Air handlers are not included. A Vision air-handler submittal was supplied for reference.

What is the reported condition?

The seller reports the units as new and unused surplus. The current photographs show the equipment in outdoor storage.

How many units are available?

Twenty RCS040D condensing units are available. Contact us to request the supporting inventory details.

What electrical service is identified?

The supplied condenser submittal and photographed nameplate identify 460V, 3-phase, 60Hz service. Electrical requirements must be verified against the nameplate of the specific unit selected.

Where is the equipment located?

The offering was presented as FOB Houston, Texas.

Can prospective buyers inspect the units?

Yes. Prospective buyers are welcome to inspect the units before purchase. Contact us to coordinate access.

Can I review the full technical submittals?

Yes. Both supplied PDFs are linked above. The 14-page condenser submittal contains the relevant RCS040D selection. The separate 45-page air-handler document is reference material only.

Start the conversation

Request pricing and supporting documentation.

Tell us your required quantity and application. We can discuss pricing, the supplied submittals, inventory details and the next verification steps.

Technical suitability and installation requirements are the buyer’s responsibility to verify with qualified professionals.